Polycarbonate + PET
Makroblend® UT1018
A (PET+PC) blend, unreinforced; impact modified, injection molding grade material that has.good dimensional stability; excellent low-temperature impact and chemical resistance.
Processes
- Injection Mold Tooling & Parts
Properties
- Chemical-resistant
Features
- Chemical Resistant
- Good Dimensional Stability
- Impact Modified
- Low Temperature Impact Resistance
Properties
General | ||||
Material Status
|
|
|||
Availability
|
|
|||
Additive
|
|
|||
Features
|
|
|||
RoHS Compliance
|
|
|||
Processing Method
|
|
Physical |
Nominal Value
|
Unit
|
Test Method
|
Density (73°F)
|
1.22
|
g/cm³
|
ISO 1183 |
Melt Volume-Flow Rate (MVR) (270°C/5.0 kg)
|
13
|
cm³/10min
|
ISO 1133 |
Molding Shrinkage 3
|
ISO 2577 | ||
Across Flow
|
0.70 to 0.90
|
%
|
|
Flow
|
0.70 to 0.90
|
%
|
|
Water Absorption
|
ISO 62 | ||
Saturation, 73°F
|
0.70
|
%
|
|
Equilibrium, 73°F, 50% RH
|
0.20
|
%
|
Mechanical |
Nominal Value
|
Unit
|
Test Method
|
Tensile Modulus (73°F)
|
290000
|
psi
|
ISO 527-1/1 |
Tensile Stress
|
ISO 527-2/50 | ||
Yield, 73°F
|
7110
|
psi
|
|
Break, 73°F
|
6670
|
psi
|
|
Tensile Strain (Yield, 73°F)
|
4.5
|
%
|
ISO 527-2/50 |
Nominal Tensile Strain at Break (73°F)
|
100
|
%
|
ISO 527-2/50 |
Flexural Modulus 4 (73°F)
|
276000
|
psi
|
ISO 178 |
Flexural Stress 4
|
ISO 178 | ||
3.5% Strain, 73°F
|
8700
|
psi
|
|
73°F
|
10200
|
psi
|
Thermal |
Nominal Value
|
Unit
|
Test Method
|
Deflection Temperature Under Load
|
|||
66 psi, Unannealed
|
226
|
°F
|
ISO 75-2/B |
264 psi, Unannealed
|
172
|
°F
|
ISO 75-2/A |
Vicat Softening Temperature
|
270
|
°F
|
ISO 306/B120 |
CLTE
|
ISO 11359-2 | ||
Flow : 73 to 131°F
|
4.4E-5
|
in/in/°F
|
|
Transverse : 73 to 131°F
|
5.0E-5
|
in/in/°F
|
|
Thermal Conductivity 5 (73°F)
|
1.4
|
Btu·in/hr/ft²/°F
|
ISO 8302 |
Electrical |
Nominal Value
|
Unit
|
Test Method
|
Surface Resistivity
|
1.0E+16
|
ohms
|
IEC 60093 |
Volume Resistivity (73°F)
|
1.0E+16
|
ohms·cm
|
IEC 60093 |
Electric Strength (73°F, 0.0394 in)
|
860
|
V/mil
|
IEC 60243-1 |
Relative Permittivity
|
IEC 60250 | ||
73°F, 100 Hz
|
3.20
|
||
73°F, 1 MHz
|
3.10
|
||
Dissipation Factor
|
IEC 60250 | ||
73°F, 100 Hz
|
2.0E-3
|
||
73°F, 1 MHz
|
0.015
|
||
Comparative Tracking Index (Solution A)
|
600
|
V
|
IEC 60112 |
Flammability |
Nominal Value
|
Unit
|
Test Method
|
Flame Rating
|
UL 94 | ||
0.06 in
|
HB
|
||
0.12 in
|
HB
|
Injection |
Nominal Value
|
Unit
|
|
Drying Temperature – Dry Air Dryer
|
230
|
°F
|
|
Drying Time – Dry Air Dryer
|
2.0 to 4.0
|
hr
|
|
Suggested Max Moisture
|
< 0.010
|
%
|
|
Suggested Shot Size
|
30 to 70
|
%
|
|
Rear Temperature
|
473 to 491
|
°F
|
|
Middle Temperature
|
482 to 500
|
°F
|
|
Front Temperature
|
491 to 509
|
°F
|
|
Nozzle Temperature
|
491 to 518
|
°F
|
|
Processing (Melt) Temp
|
500 to 536
|
°F
|
|
Mold Temperature
|
122 to 212
|
°F
|
|
Back Pressure
|
725 to 2180
|
psi
|
|
Vent Depth
|
9.8E-4 to 3.0E-3
|
in
|
Notes
3600 bar
40.079 in/min
5Across Flow
Ready to Get Started?
Fill out the quick form below and one of our manufacturing experts will be in touch with you soon.